3. TECHNICAL DATA
3.1 Product drawing
All measures have the unit mm.
1 Direction of air flow "V"
2 Depth of screw max. 10 mm
3 Tightening torque 0.8±0.15 Nm
4 Cable diameter: min. 6 mm, max. 12 mm; tightening torque: 2±0.3 Nm
Item no. 11736-5-9970 · ENG · Revision 83823 · Release 2014-12-09 · Page 4 / 10